Royce Aqua 22 measurement parameters

Portable TSS meter for wastewater treatment.

Measure total suspended solids from 0 to 20,000 mg/L with a rugged portable instrument designed for routine wastewater process checks.

Royce Aqua 22 sludge blanket sensor and handheld meter positioned beside settlement tanks

Measure total suspended solids at the tank side.

Total suspended solids (TSS) is the concentration of suspended particles present in water or wastewater. Routine TSS checks give operators immediate field information when comparing treatment stages, process streams and sampling points.

The Royce Aqua 22 provides a portable TSS reading directly beside the process. Its infrared absorption sensor measures suspended-solids concentration from 0 to 20,000 mg/L, helping teams make repeatable field checks without carrying a separate benchtop instrument to every sampling point.

What TSS tells you—and how the Aqua 22 measures it.

The suspended-solids sensor converts an infrared absorption response into a TSS concentration reading in mg/L, giving operators immediate information beside the process.

01 / TSS MEASUREMENT

Infrared absorption measures TSS concentration

The sensor passes infrared energy through the process liquid. Suspended particles reduce the detected signal and the calibrated response is converted into a TSS concentration reading from 0 to 20,000 mg/L.

  • Immediate TSS concentration reading at the tank side
  • Designed for routine municipal and industrial wastewater checks
  • Approximately ±5% accuracy with 1% repeatability

A REPEATABLE TSS CHECK

From process sample to useful TSS reading.

Use the same safe sampling position and operating method whenever possible so that changes in the TSS reading reflect the process rather than the measurement routine.

01.

Prepare

Inspect the sensor and cable, connect the suspended-solids sensor, power the analyser and select TSS mode and the required stored location.

02.

Position

Use a safe, representative position. Return to the same sampling point whenever possible so that changes reflect the process rather than the location.

03.

Lower

Lower the IP68 suspended-solids sensor steadily into the process liquid. Keep the IP65 handheld analyser dry and above the tank.

04.

Read

Allow the reading to settle, then note the TSS concentration in mg/L. Follow the same immersion position and timing for comparable routine checks.

05.

Record

Store the result against one of nine internal locations. Date and time stamping helps operators compare checks and build a traceable field record.

06.

Rinse

After measurement, withdraw and rinse the wetted sensor in line with site procedures. Regular inspection and calibration support dependable field performance.

Why choose the Royce Aqua 22 for portable TSS checks?

Purpose-built field features help wastewater teams take, read and record TSS measurements across treatment works.

TSS and sludge depth in one system

Use TSS mode for suspended-solids concentration and LEVEL mode to identify the sludge interface and read its depth.

Calibration stays with the sensor

Each smart serialised sensor stores its calibration data internally for straightforward interchange between compatible handheld meters.

Clear readings outdoors

The high-clarity LCD is designed for bright outdoor conditions, with or without polarised safety glasses.

Lightweight field format

The approximately 320 g handheld supports practical one-handed operation between tanks and sampling points.

UK application and service support

PMA provides Royce Aqua selection, application guidance, service and calibration support from the United Kingdom.

Where portable TSS measurement is used.

Portable TSS measurement is used where operators need immediate suspended-solids information beside the process. The Royce Aqua 22 supports routine checks across municipal and industrial wastewater treatment.

ApplicationHow the TSS reading is used
Aeration basinsCheck suspended-solids concentration during routine aeration-basin operation.
Sequencing batch reactorsCompare suspended-solids concentration during selected treatment-cycle stages.
Return activated sludgeCheck suspended-solids concentration in RAS streams as part of routine process monitoring.
Municipal wastewater treatmentCarry out portable TSS checks across multiple tanks and treatment assets.
Industrial biological treatmentSupport day-to-day monitoring where suspended solids affect process stability.

Portable TSS meter specifications.

Key Royce Aqua 22 specifications relevant to portable TSS measurement.

SpecificationRoyce Aqua 22
TSS measuring range0–20,000 mg/L
Measurement principleInfrared absorption
AccuracyApproximately ±5%
Repeatability1%
Handheld protectionIP65
Sensor protectionIP68
Handheld weightApproximately 320 g
Standard cable10 m polyurethane
Data organisation9 locations with date/time stamping

Specifications are based on the current PMA Royce Aqua 22 brochure and may be subject to product development. Confirm critical requirements with PMA before specification. For an overview of the complete portable measurement system, visit the Royce Aqua 22 product page.

Wastewater operator holding the Royce Aqua 22 portable TSS meter at a treatment works


We use the information you provide in this form to respond to your enquiry. Please refer to our privacy policy for how we protect your data.

This site is protected by Cloudflare Turnstile. Cloudflare’s Privacy Policy and Terms of Use apply.